The UNIONC JGT series is two stage air driven gas booster.Fitting for low inlet pressure but high outlet pressure,two pressure chamber,high and low.Then the pump can work normally even low supplying air .
Application in tube,hose valve ,pressure vessel leak testing,refilling nitrogen,relief valve nitorgen calibration,refilling damper,deepsea pressure simulation ,etc.
A:Gas inlet B:Gas outlet C:Drive air
Ordering Table
UNIOC Pa=drive air Pi=Gas inlet Po=Gas outlet | |||||||
Model | Ratio | Min, gas inletPi(bar) | Max. rated outlet(bar) | Po=ratio*Pa+Pi | Gas inlet port | Gas outlet port | Max. flowL/min |
JGT7/15 | 15:1 | 4.4 | 131 | 15Pa+Pi | PT3/8" | PT3/8" | 215 |
JGT7/25 | 25:1 | 4.4 | 235 | 25Pa+Pi | PT3/8" | PT3/8" | 186 |
JGT15/40 | 40:1 | 8 | 332 | 40Pa+Pi | PT1/4" | PT1/4" | 85 |
JGT15/60 | 60:1 | 8 | 498 | 60Pa+Pi | PT1/4" | PT1/4" | 72 |
JGT30/60 | 60:1 | 28 | 498 | 60Pa+Pi | PT1/4" | PT1/4" | 85 |
JGT15/100 | 100:1 | 8 | 830 | 100Pa+Pi | PT3/8" | PT3/8" | 72 |
JGT30/100 | 100:1 | 28 | 830 | 100Pa+Pi | PT1/4" | PT1/4" | 80 |